Problems with Intermatic timers are caused by defective trippers, incorrect wiring, tripped circuit breakers, a faulty time clock motor and incorrectly set power terminals. Hi Chinh, if the clock gears are not moving, check the two small white wires going to the motor, on the reverse side of the timer mechanism. Miriam, I would check that the timer dogs are pushed fully onto the dial, and the dial is tight also check the screw for tightness in the center of the dial. Inspect that the gear behind the timeclock dial, is turning (very slowly), and that nothing is caught up in the gears, like sand or a lizards tail, or bugs, etc. Rich. how do I check the manual over ride switch to see if it is off? For some reason, whenever my timer hits the time its supposed to kick the pump on, it gets stuck at that time and the pump wont come on. Everythings OK now, unit works just fine. Back when I was a young technician I was taught to always look for the easy things and use all my senses. Still no luck. Basically 12 real life hours equals about 14 on the timer. The dial turns, but when it gets to the trippers, both now, the dial stops & there is no sound the gears are working I am not an electrician but I can do small repairs. March 16, 2022 by WildRiverCountry. Inside, the 1 gear on the right side can be removed to access a metal bar. You should be able to see the gears moving. Hi John, the trip mechanism on the clock, the switch, could be worn to the point where the tripper does not make good contact. No Power to the Timer Having no power to your pool timer is a common problem and will occur because of three reasons: The Circuit Breaker has tripped. Grab your torch and shine it in the holes. What Im wanting to do is just disable the turn off/on and just keep power 24/7. I realized today that my pump has been on for 11 hours, but the clock has only moved a few hours. My Polaris booster pump ONLY turns on via the trippers. Pool timers can also be used to automatically turn on/off pool lights or other outdoor lighting around the pool. If test shows that timer is not turning ON-and-OFF, then timer is bad or trippers are worn and need replacement. Timer not tripping pump on. Elite. how can I turn the time bar back down to the 6 oclock point so my timer will turn the lights on some how it is in the 2 oclock position an will not turn on automatically, Your email address will not be published. The problem was the connections I made inside my main electrical panel, I used romex wire nuts to attach the solid core #10 wire that I used to hook up the timer to the existing stranded #10 wire and it didnt make the connection so to speak. hi, I have a smart pump for my pool, the time clock turns on in the morning and at the same time I see that the pump has power but it doesnt turn on, I have to turn on manually, is it something that the electrician has to connect to the pump so they are synchronized? Sometimes the on/off switch on Intermatic and other mechanical timers can get tight. It I set the timer again it will jeep time until it gets to the next dog ear. Hi, then the power for the clock must be from the switch, and not from the breaker? make sure it hasnt tripped and is switched on. 1-48 of 242 results for "pool timer trippers" RESULTS. Sometimes we suspect the timer is the issue but it turns out its really the pump or the wiring between the pump and the timer. The timer not working is for the pump. This is hard to check if you are not qualified. Could I send you a picture of my setup? If its not, it wont work properly. I turned the breaker off and back on and still not working. Any idea what may be causing this? If all looks well, and the gears are still not turning, you may need to replace the mechanism. Things are working fine and all of a sudden the pool pump did not start in the morning. I dont see timer gears rotating on any power going to the pump or salt system. You should always be able to switch your pump on and off manually at the timer. If you have both pins take notice of there position and then come back in a few hours and see if they have changed from the spot they were in when you last looked. If the trippers are loose, then they could slip and cause issues with the pump turning on/off at the correct times. HI Ben, yes just remove the OFF tripper, and the clock will always be ON. I look through the window of the panel and see the gears running well. Intermatic timers are common among pool owners and typically last a long time, but they also can come with problems and may need to be fixed. what causes timer on/off pins to bend and how can i prevent timer pins from bending. the trippers are even slightly damaged the timer won't work correctly. I bought a new timer and replace the T104 timer clock. Is it possible to do this by loosening the timer screw a bit? The tabs on the back of the timer may have fused together, or the tabs on the stationary switch at the rear of the motor, from a power surge. I visually checked the clock motor and it was good. I tried to change the on tripper due to Daylight savings time & dropped the screw. The clock is powered from the Line 1 terminal correct? So just turn the adjustment hold down screw on the timer pin counter clockwise about a full turn and then you will be able to slide the on or off pin to the right time on the timer wheel. the timer was directly plugged into a gfci and the pump directly into the timer. Timer not tripping pump on. To set it, you just move the on/off "trippers" where you want them. When I turned it back on now the pool clock goes backwards. This will disengage the dial from the . My intermatic timer is about two years old as well. If no damage is seen and the wires are intact, and the motor gears are not turning, and you find nothing stuck in the gears (sand, insects, any obstruction), and some spray WD-40 on the gears and a little push from a small flathead screwdriver does not help then, you can assume that the motor is dead, at which point you can replace the motor itself with the exact replacement, or replace the entire clock. i have an oval pool that is closed for the winter but there ha been a problem. Im going to try inspecting the back of the timer to see if a wire go knocked loose or something. Shannon, compare the wiring to the diagram for Line and Load (line is power coming in, Load is power out to your pump). ft. home is a 3 bed, 4.0 bath property. Is there anything else I can do or do I need to get a new one? One morning I noticed my pool didnt automatically turn off. Southern Queensland Country Tourism CEO Peter Homan says water park could convert 'day trippers' to overnight visitors to Toowoomba The region's peak tourism body has claimed a widely requested water park could increase Toowoomba's appeal to a new era of visitors, as council says a park was not a priority in the coming decade. Depends maybe on what it is getting stuck on, or what is catching the tripper, and are the motor gears still turning when it gets stuck? Take a good look at the position of the pins and write down the locations. Also be sure that the front dial is engaged with the gear located behind the dial. There is no replacement on/off switch available, you would need a new T104 mechanism, unless you are able to melt some solder, or fix it with duct tape or something, lol! Since it came out of the box today, it probably is not trash in the gears.It seems the plastic gears and/or the coil in the clock mechanism are not strong enough to engage the on/off points or not for long. But my new timer will not work either. AJH Trade Group Australia Pool Equipment | Pool Lifestyle | Pool Heating | Pool Maintenance | Pool Problems, what to do when the pump circuit breaker continually trips. I looked to see if the gears on the timer are running. Video of the Day Trippers Hello, newer pool guy here. Look at the copper tabs on the back and observe the action as you flip the switch manually on and off. Clock not turning or making any sound. Hi Rich, is one of those wires (white?) Hi Jennifer, power down (shut off the breaker) again, to see if it will switch back. Ive seen it happen from lightning strikes, or insect infestation. Set the current time to the center time pointer, pointing downward at 6 oclock. A couple of weeks in, I noticed it was not keeping time. You can manually engage it by turning it and then it will run and even SHUT OFF when its supposed to. Then turn the breaker, that the time clock is connected to, off and back on again. NEW CONSTRUCTION. P.S. Okay, so lets move on to the Intermatic Pool Timer troubleshooting and figure out why your timer is not working. It is a mechanical issue between the trippers and the switch lever. Or might find something else. "@type": "BlogPosting",
$115 Providence distortion MIJ - $120 All working perfectly Should be clear in photos which include boxes, others will be bubble wrapped and . Check the wiring also, looking for broken wires or loose connections, which could explain the breaker tripping as well. When you flip the switch does it separate and reconnect the tabs? As an Amazon Associate we earn from qualifying purchases. Thanks in advanced. Ordered new ones. I can, however, hear an intermittent click as if the mechanism is trying to switch on. MLS # 6354744 Hi Jeff, it could be that the terminals in the rear of the clock mechanism are fuse-welded together, and not separating like normal, when the on/off switch is flipped. Is there a control board, PCB in the panel that could have problems? If thats all ok, shut off breaker and depress tab at the top, to release the mechanism from the box, and look at the copper tabs in the back. Thank you, I dont know about the box, was just told the mechanical timer a T104 is needed. "height": "219",
Clean the gears with a toothbrush if you see debris or gunk in them. These are the trippers that came with the time clock. After a few days its off by 6 or 7 hrs but still turns on and off fine any suggestions? Either that or if an older clock, the motor may be failing, or the switch mechanism worn (the part that is tripped by the tripper). Or may be bent and not come together. Before using your timer to optimize your pump, you need to determine that your pool's pH, alkalinity, and calcium hardness are 7.4 to 7.6, 100 to 150 ppm, and 150 to 400 ppm, respectively. I have a 2 speed pump. Only perform this step if you are qualified. The T104RD89 timer will work with a swimming pool motor as long as the motor is 240 VAC and is under 5 HP which is what this timer is rated for. Intermatic timers can typically be fixed by checking theres power to the timer, resetting the time, renewing the ON/OFF trippers and renewing the gears or timer motor. Gas pool heaters are one of the best additions to a pool, but they are the most high-maintenance piece of equipment on, 22,000 pool parts in stock! Intermatic time clocks are the workhorse of your pool equipment collection, and oftentimes outlive the equipment they control. "dateModified": "1/10/2020",
Do not remove the screws from the trippers. I hope this helps. We have a comprehensive article that covers what to do when the pump circuit breaker continually trips. If power is reaching the clock, but the motor gears are not turning, that usually means either something is jammed in the gears, or the timer motor has burned out. Monday the clock face was free spinning, today when I got home it had broken and fallen off. If you dont think the mechanism is the issue, move onto the next step. Are the trippers slid all the way onto the dial fully? Also be sure that the dial is not pulled out, but is engaging the gear behind the dial. If I manually flip the switch nothing happens. Pool pump comes on fine with the on dog, but wont turn off. If still not working, check the wire connections and then test voltage on the clock incoming wires, outgoing wires, and then at the pump motor the problem lies, where the power dies, as they say. You will have live wires exposed and they can kill you if you touch them. Hi Matthew T104 can only turn one pump on and off. If moving that is difficult, you could just avoid using the switch and turn the pump off with the timeclock instead, always keeping the switch on, and maybe taping the switch, to remind people not to use the switch. See the point above if it is. Richard, pull the mechanism out of the box by releasing the clip at the top and inspect the copper strips and pads on the rear. There is a switch control panel and replaced the 20amps DP switch as well. screwfindinganame on June 18, 2013 at 11:36 pm What happened? Not two OFF trippers? It could also be loose wires, either on the time clock terminal board, or on the timer motor. Use Green ON tripper for T100 Series timers and the silver ON tripper is for all other models. I just replaced my T101 timer 2 years ago. 3 Baths. On occasion the two points that are used for setting the ON and OFF times for the pool pump get damaged or loosen. Resolved! Many thanks! The pool timers I have had down there . There is a second switch between the breaker and the timer. So out comes the soldering gun and the shrink wraps and that did the trick. Hello have a question some what related. Next step would be to inspect the wires going from timer to pump motor, or test them for continuity. Two days ago after my pool pump shut off automatically I decided to turn it back on because the pool was still dirty. everything seems to be working correctly, but i can not turn the pump on or off by tripping the mechanism. But first, pull the mechanism from the box by releasing the tab at the top (be sure breaker is turned off, first), and inspect the gears and copper tabs on the back, to look for something clogging up the works, insects, lizards, sand, etc.